91. Spacers are provided between adjacent coils

to provide free passage to the cooling oil
to insulate the coils from each other
both (A) and (B)
none of the above

Subscribe on YouTube

provided between adjacent coils" class="read-more button" href="https://exam.pscnotes.com/mcq/spacers-are-provided-between-adjacent-coils/#more-47489">Detailed SolutionSpacers are provided between adjacent coils

94. If the supply frequency to the transformer is increased, the iron loss will

not change
decrease
increase
any of the above

Join Our Telegram Channel

viewBox="0 0 576 512"> Subscribe on YouTube
button" href="https://exam.pscnotes.com/mcq/if-the-supply-frequency-to-the-transformer-is-increased-the-iron-loss-will/#more-47180">Detailed SolutionIf the supply frequency to the transformer is increased, the iron loss will

95. In a power or distribution transformer about 10 per cent end turns are heavily insulated

to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns
to reflect the line surge and save the winding of a transformer from damage
none of the above

Detailed SolutionIn a power or distribution transformer about 10 per cent end turns are heavily insulated

96. Iron loss of a transformer can be measured by

low power factor wattmeter
unity power factor wattmeter
frequency meter
any type of wattmeter

Subscribe on YouTube

transformer can be measured by" class="read-more button" href="https://exam.pscnotes.com/mcq/iron-loss-of-a-transformer-can-be-measured-by/#more-47085">Detailed SolutionIron loss of a transformer can be measured by

97. Negative voltage regulation is indicative that the load is

capacitive only
inductive only
inductive or resistive
none of the above

Join Our Telegram Channel

48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube the load is" class="read-more button" href="https://exam.pscnotes.com/mcq/negative-voltage-regulation-is-indicative-that-the-load-is/#more-47072">Detailed SolutionNegative voltage regulation is indicative that the load is

98. Losses which occur in rotating electric machines and do not occur in trans formers are

friction and windage losses
magnetic losses
hysteresis and eddy current losses
copper losses

Join Our Telegram Channel

512"> Subscribe on YouTube href="https://exam.pscnotes.com/mcq/losses-which-occur-in-rotating-electric-machines-and-do-not-occur-in-trans-formers-are/#more-46712">Detailed SolutionLosses which occur in rotating electric machines and do not occur in trans formers are

99. The no load current in a transformer lags behind the applied voltage by an angle of about

180°
120°
90°
75°

Subscribe on YouTube

about" class="read-more button" href="https://exam.pscnotes.com/mcq/the-no-load-current-in-a-transformer-lags-behind-the-applied-voltage-by-an-angle-of-about/#more-46488">Detailed SolutionThe no load current in a transformer lags behind the applied voltage by an angle of about

100. During open circuit test of a transformer

primary is supplied rated voltage
primary is supplied full-load current
primary is supplied current at reduced voltage
primary is supplied rated kVA

Subscribe on YouTube

class="read-more button" href="https://exam.pscnotes.com/mcq/during-open-circuit-test-of-a-transformer/#more-46376">Detailed SolutionDuring open circuit test of a transformer