101. If a transformer is switched on to a voltage more than the rated voltage

its power factor will deteriorate
its power factor will increase
its power factor will remain unaffected
its power factor will be zero

Subscribe on YouTube

voltage more than the rated voltage" class="read-more button" href="https://exam.pscnotes.com/mcq/if-a-transformer-is-switched-on-to-a-voltage-more-than-the-rated-voltage/#more-46353">Detailed SolutionIf a transformer is switched on to a voltage more than the rated voltage

103. No-load on a transformer is carried out to determine

copper loss
magnetising current
magnetising current and loss
efficiency of the transformer

Subscribe on YouTube

out to determine" class="read-more button" href="https://exam.pscnotes.com/mcq/no-load-on-a-transformer-is-carried-out-to-determine/#more-46267">Detailed SolutionNo-load on a transformer is carried out to determine

104. The maximum load that a power transformer can carry is limited by its

temperature rise
dielectric strength of oil
voltage ratio
copper loss

Subscribe on YouTube

button" href="https://exam.pscnotes.com/mcq/the-maximum-load-that-a-power-transformer-can-carry-is-limited-by-its/#more-46083">Detailed SolutionThe maximum load that a power transformer can carry is limited by its

105. Hysteresis loss in a transformer varies as (Bmax = maximum flux density)

$${{ ext{B}}_{max }}$$
$${{ ext{B}}_{max }}^{1.6}$$
$${{ ext{B}}_{max }}^{1.85}$$
$${{ ext{B}}_{max }}^{2.4}$$

Detailed SolutionHysteresis loss

in a transformer varies as (Bmax = maximum flux density)

106. Which type of winding is used in 3phase shell-type transformer?

Circular type
Sandwich type
Cylindrical type
Rectangular type

Join Our Telegram Channel

48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube href="https://exam.pscnotes.com/mcq/which-type-of-winding-is-used-in-3phase-shell-type-transformer/#more-45339">Detailed SolutionWhich type of winding is used in 3phase shell-type transformer?

107. Insertion of resistance in the rotcir of an induction motor to develop a given torque

decreases the rotor current
increases the rotor current
rotor current becomes zero
rotor current rernains same

Subscribe on YouTube

button" href="https://exam.pscnotes.com/mcq/insertion-of-resistance-in-the-rotcir-of-an-induction-motor-to-develop-a-given-torque/#more-45261">Detailed SolutionInsertion of resistance in the rotcir of an induction motor to develop a given torque

108. For given applied voltage, with the increase in frequency of the applied voltage

eddy current loss will decrease
eddy current loss will increase
eddy current loss will remain unchanged
none of the above

Detailed Solution

Subscribe on YouTube

class="screen-reader-text">For given applied voltage, with the increase in frequency of the applied voltage

109. Which of the following protection is normally not provided on small distribution transformers?

Overfluxing protection
Buchholz relay
Overcurrent protection
All of the above

Join Our Telegram Channel

class="youtube-subscribe-button"> Subscribe on YouTube small distribution transformers?" class="read-more button" href="https://exam.pscnotes.com/mcq/which-of-the-following-protection-is-normally-not-provided-on-small-distribution-transformers/#more-45081">Detailed SolutionWhich of the following protection is normally not provided on small distribution transformers?

110. A transformer core is laminated to

reduce hysteresis loss
reduce eddy current losses
reduce copper losses
reduce all above losses

Subscribe on YouTube

to" class="read-more button" href="https://exam.pscnotes.com/mcq/a-transformer-core-is-laminated-to/#more-45062">Detailed SolutionA transformer core is laminated to