2. Arc in a circuit breaker is interrupted at

zero current
maximum current
minimum voltage
maximum voltage

Join Our Telegram Channel

448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube
href="https://exam.pscnotes.com/mcq/arc-in-a-circuit-breaker-is-interrupted-at/#more-59750">Detailed SolutionArc in a circuit breaker is interrupted at

3. The relay with inverse time characteristic will operate within

1.5 sec
5 to 10 sec
5 to 20 sec
20 to 30 sec E. none of the above

Join Our Telegram Channel

64 74.6 75.5c-23.5 6.3-42 24.9-48.3 48.6-11.4 42.9-11.4 132.3-11.4 132.3s0 89.4 11.4 132.3c6.3 23.7 24.8 41.5 48.3 47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube
inverse time characteristic will operate within" class="read-more button" href="https://exam.pscnotes.com/mcq/the-relay-with-inverse-time-characteristic-will-operate-within/#more-59748">Detailed SolutionThe relay with inverse time characteristic will operate within

4. Which of the following circuit breakers has high reliability and minimum maintenance ?

Air blast circuit breakers
Circuit breaker with SF6 gas
Vacuum circuit breakers
Oil circuit breakers

Detailed SolutionWhich of

the following circuit breakers has high reliability and minimum maintenance ?

5. The interaction between a transmission line and communication line is minimized by

transposing transmission as well as communication lines
increasing the height of the trans-mission line tower
increasing the distance between the two lines
all of the above

Subscribe on YouTube

line and communication line is minimized by" class="read-more button" href="https://exam.pscnotes.com/mcq/the-interaction-between-a-transmission-line-and-communication-line-is-minimized-by/#more-59536">Detailed SolutionThe interaction between a transmission line and communication line is minimized by

6. Oil switches are employed for

low currents circuits
low voltages circuits
high voltages and large currents circuits
all circuits

Join Our Telegram Channel

288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube for" class="read-more button" href="https://exam.pscnotes.com/mcq/oil-switches-are-employed-for/#more-59482">Detailed SolutionOil switches are employed for

7. Which of the following devices will receive voltage surge first travelling on the transmission line ?

Lightning arresters
Relays
Step-down transformer
Switchgear

Detailed SolutionWhich of the following

devices will receive voltage surge first travelling on the transmission line ?

8. For cost and safety, the outdoor substations are installed for voltages above

11 kV
33 kV
60 kV
110 kV

Detailed SolutionFor cost

and safety, the outdoor substations are installed for voltages above

9. An efficient and a well designed protective relaying should have

good selectivity and reliability
economy and simplicity
high speed and selectivity
all of the above

Subscribe on YouTube

well designed protective relaying should have" class="read-more button" href="https://exam.pscnotes.com/mcq/an-efficient-and-a-well-designed-protective-relaying-should-have/#more-58499">Detailed SolutionAn efficient and a well designed protective relaying should have

10. On which of the following effects of electric current a fuse operates?

Photoelectric effect
Electrostatic effect
Heating effect
Magnetic effect

Subscribe on YouTube

button" href="https://exam.pscnotes.com/mcq/on-which-of-the-following-effects-of-electric-current-a-fuse-operates/#more-58110">Detailed SolutionOn which of the following effects of electric current a fuse operates?

Test 1Test 2
Exit mobile version