Skip to content

MCQ and Quiz for Exams

  • Home
  • Telangana and Karnataka
  • Bihar
  • Haryana
  • Assam
  • Jammu and kashmir

Single phase induction motors

41. A shaded pole motor does not possess

[amp_mcq option1=”centrifugal switch” option2=”capacitor” option3=”commutator” option4=”all of the above” correct=”option4″]

Detailed SolutionA shaded pole motor does not possess

42. Locked rotor current of a shaded pole motor is

[amp_mcq option1=”equal to full load current” option2=”less than full load current” option3=”slightly more than full load current” option4=”several times the full load current” correct=”option4″]

Detailed SolutionLocked rotor current of a shaded pole motor is

43. The speed of a universal motor is generally reduced by using

[amp_mcq option1=”gear trains” option2=”V-belts” option3=”brakes” option4=”chains” correct=”option1″]

Detailed SolutionThe speed of a universal motor is generally reduced by using

44. Most of the fractional horsepower motors have either

[amp_mcq option1=”hard and annealed bearings” option2=”ball or roller bearings” option3=”soft and porous bearings” option4=”plain or sleeve bearings” correct=”option2″]

Detailed SolutionMost of the fractional horsepower motors have either

45. The speed/load characteristics of a universal motor is same as that of

[amp_mcq option1=”D.C. motor” option2=”D.” option3=”motor B.” option4=”none of the above” correct=”option4″]

Detailed SolutionThe speed/load characteristics of a universal motor is same as that of

46. If a single phase induction motor runs slower than normal, the most likely defect is

[amp_mcq option1=”worn bearings” option2=”short-circuit in the winding” option3=”open-circuit in the winding” option4=”none of the above” correct=”option3″]

Detailed SolutionIf a single phase induction motor runs slower than normal, the most likely defect is

47. In split phase motor main winding is of

[amp_mcq option1=”thin wire placed at the top of the slots” option2=”thin wire placed at the bottom of the slots” option3=”thick wire placed at the bottom of the slots” option4=”thick wire placed at the top of the? slots” correct=”option1″]

Detailed SolutionIn split phase motor main winding is of

48. A shaded pole motor can be used for

[amp_mcq option1=”toys” option2=”hair dryers” option3=”circulators” option4=”any of the above” correct=”option1″]

Detailed SolutionA shaded pole motor can be used for

49. The repulsion start induction run motor is used because of

[amp_mcq option1=”good power factor” option2=”high efficiency” option3=”minimum cost” option4=”high starting torque” correct=”option4″]

Detailed SolutionThe repulsion start induction run motor is used because of

50. Which of the following motors is used in a situation where load increases with speed ?

[amp_mcq option1=”Induction motor” option2=”Three-phase series motor” option3=”Schrage motor” option4=”Hysteresis motor” correct=”option1″]

Detailed SolutionWhich of the following motors is used in a situation where load increases with speed ?

Page 1Page 2Page 3Page 4Page 5

Test 1Test 2
© PSC Notes- Serving since 2015
  • Home
  • Telangana and Karnataka
  • Bihar
  • Haryana
  • Assam
  • Jammu and kashmir
Go to mobile version