{"id":6920,"date":"2024-04-15T02:36:09","date_gmt":"2024-04-15T02:36:09","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=6920"},"modified":"2024-04-15T02:36:09","modified_gmt":"2024-04-15T02:36:09","slug":"a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/","title":{"rendered":"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0"},"content":{"rendered":"<p>\r\n    <!-- Check if it's an AMP page -->\r\n            <!-- Non-AMP version -->\r\n        <div class=\"mcq-container\" data-quiz-id=\"quizState_6a990aaf98459\">\r\n                                            <div class=\"option\" data-option-key=\"option1\" data-is-correct=\"false\">\r\n                    7\u00c2\u00b0                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option2\" data-is-correct=\"false\">\r\n                    10\u00c2\u00b0                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option3\" data-is-correct=\"true\">\r\n                    12\u00c2\u00b0                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option4\" data-is-correct=\"false\">\r\n                    17\u00c2\u00b0                <\/div>\r\n                            \r\n            <!-- Feedback messages for non-AMP -->\r\n            <div class=\"feedback\" data-feedback=\"wrong\">Answer is Right!<\/div>\r\n            <div class=\"feedback\" data-feedback=\"right\">Answer is Wrong!<\/div>\r\n        <\/div>\r\n\r\n        <script>\r\n        document.addEventListener('DOMContentLoaded', function () {\r\n            var containers = document.querySelectorAll('.mcq-container');\r\n\r\n            containers.forEach(function(container) {\r\n                var options = container.querySelectorAll('.option');\r\n                var feedbackSelect = container.querySelector('[data-feedback=\"select\"]');\r\n                var feedbackWrong = container.querySelector('[data-feedback=\"wrong\"]');\r\n                var feedbackRight = container.querySelector('[data-feedback=\"right\"]');\r\n\r\n                options.forEach(function(option) {\r\n                    option.addEventListener('click', function() {\r\n                        var selectedOption = option.getAttribute('data-option-key');\r\n                        var isCorrect = option.getAttribute('data-is-correct') === 'true';\r\n\r\n                        \/\/ Remove previous selections\r\n                        options.forEach(function(opt) {\r\n                            opt.classList.remove('correct', 'incorrect');\r\n                        });\r\n\r\n                        \/\/ Add the correct\/incorrect class\r\n                        if (isCorrect) {\r\n                            option.classList.add('correct');\r\n                            feedbackRight.hidden = false;\r\n                            feedbackWrong.hidden = true;\r\n                        } else {\r\n                            option.classList.add('incorrect');\r\n                            feedbackRight.hidden = true;\r\n                            feedbackWrong.hidden = false;\r\n                        }\r\n\r\n                        \/\/ Hide select feedback\r\n                        feedbackSelect.hidden = true;\r\n                    });\r\n                });\r\n            });\r\n        });\r\n        <\/script>\r\n    \r\n    <!--more--><\/p>\n<p>The correct answer is C. 12\u00c2\u00b0.<\/p>\n<p>The resultant active earth pressure is the sum of the vertical and horizontal components of the active earth pressure. The vertical component of the active earth pressure is equal to the weight of the backfill, while the horizontal component is equal to the product of the lateral earth pressure coefficient and the active earth pressure.<\/p>\n<p>The lateral earth pressure coefficient is a function of the angle of internal friction of the backfill and the angle of wall friction. The angle of internal friction of the backfill is equal to the angle of surcharge, while the angle of wall friction is equal to 7\u00c2\u00b0.<\/p>\n<p>The resultant active earth pressure will act at a distance of 2 m above the base of the wall, because the vertical component of the active earth pressure is equal to the weight of the backfill, which is acting at the base of the wall.<\/p>\n<p>The resultant active earth pressure will be inclined to the horizontal at an angle of 12\u00c2\u00b0, because the horizontal component of the active earth pressure is equal to the product of the lateral earth pressure coefficient and the active earth pressure, which is equal to the product of the angle of internal friction of the backfill and the angle of wall friction.<\/p>\n<p>The following is a brief explanation of each option:<\/p>\n<ul>\n<li>Option A: 7\u00c2\u00b0. This is the angle of wall friction. The resultant active earth pressure will not act at an angle of 7\u00c2\u00b0 to the horizontal, because the horizontal component of the active earth pressure is not equal to the product of the lateral earth pressure coefficient and the active earth pressure.<\/li>\n<li>Option B: 10\u00c2\u00b0. This is the angle of surcharge. The resultant active earth pressure will not act at an angle of 10\u00c2\u00b0 to the horizontal, because the horizontal component of the active earth pressure is not equal to the product of the lateral earth pressure coefficient and the active earth pressure.<\/li>\n<li>Option C: 12\u00c2\u00b0. This is the correct answer. The resultant active earth pressure will act at an angle of 12\u00c2\u00b0 to the horizontal, because the horizontal component of the active earth <div class=\"telegram-channel-container\">\r\n        <a href=\"https:\/\/t.me\/pscnotes2025\" target=\"_blank\" class=\"telegram-channel-button\">\r\n            <span class=\"telegram-icon\">\r\n                <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 496 512\">\r\n                    <path fill=\"white\" d=\"M248,8C111,8,0,119,0,256s111,248,248,248s248-111,248-248S385,8,248,8z M362,177L320,367c-3,14-10,18-20,14l-56-41l-27,26 c-3,3-5,5-10,5l4-63L323,196c5-5-1-7-8-3l-98,62l-42-13c-9-3-10-9,2-14l162-63C351,160,365,164,362,177z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Join Our Telegram Channel\r\n        <\/a>\r\n    <\/div> pressure is equal to the product of the lateral earth pressure coefficient and the active earth pressure.<\/li>\n<li>Option D: 17\u00c2\u00b0. This is not the correct answer. The resultant active earth pressure will not <div class=\"youtube-subscribe-container\">\r\n        <a href=\"https:\/\/www.youtube.com\/channel\/UCNHT8lW-JmLC68rjBfZhdkg?sub_confirmation=1\" target=\"_blank\" class=\"youtube-subscribe-button\">\r\n            <span class=\"youtube-icon\">\r\n                <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\">\r\n                    <path d=\"M549.7 124.1c-6.3-23.7-24.8-42.3-48.3-48.6C458.8 64 288 64 288 64S117.2 64 74.6 75.5c-23.5 6.3-42 24.9-48.3 48.6-11.4 42.9-11.4 132.3-11.4 132.3s0 89.4 11.4 132.3c6.3 23.7 24.8 41.5 48.3 47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Subscribe on YouTube\r\n        <\/a>\r\n    <\/div> act at an angle of 17\u00c2\u00b0 to the horizontal, because the horizontal component of the active earth pressure is not equal to the product of the lateral earth pressure coefficient and the active earth pressure.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Subscribe on YouTube<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[646],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0\" \/>\n<meta property=\"og:description\" content=\"Join Our Telegram Channel Subscribe on YouTube\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-15T02:36:09+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/","og_locale":"en_US","og_type":"article","og_title":"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0","og_description":"Join Our Telegram Channel Subscribe on YouTube","og_url":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-15T02:36:09+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/","url":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/","name":"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-15T02:36:09+00:00","dateModified":"2024-04-15T02:36:09+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/a-retaining-wall-6m-high-supports-a-backfill-with-a-surcharge-angle-of-10a-the-back-of-the-wall-is-inclined-to-the-vertical-at-a-positive-batter-angle-of-5a-if-the-angle-of-wall-friction\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"mcq","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/"},{"@type":"ListItem","position":3,"name":"Civil engineering","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/civil-engineering\/"},{"@type":"ListItem","position":4,"name":"Soil mechanics and foundation","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/civil-engineering\/soil-mechanics-and-foundation\/"},{"@type":"ListItem","position":5,"name":"A retaining wall 6m high supports a backfill with a surcharge angle of 10\u00c2\u00b0. The back of the wall is inclined to the vertical at a positive batter angle of 5\u00c2\u00b0. If the angle of wall friction is 7\u00c2\u00b0, then the resultant active earth pressure will act at a distance of 2 m above the base and inclined to the horizontal at an angle of A. 7\u00c2\u00b0 B. 10\u00c2\u00b0 C. 12\u00c2\u00b0 D. 17\u00c2\u00b0"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/6920"}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=6920"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/6920\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=6920"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=6920"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=6920"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}