{"id":6000,"date":"2024-04-15T02:22:23","date_gmt":"2024-04-15T02:22:23","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=6000"},"modified":"2024-04-15T02:22:23","modified_gmt":"2024-04-15T02:22:23","slug":"other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/","title":{"rendered":"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable"},"content":{"rendered":"<p>\r\n    <!-- Check if it's an AMP page -->\r\n            <!-- Non-AMP version -->\r\n        <div class=\"mcq-container\" data-quiz-id=\"quizState_6a9942bcac594\">\r\n                                            <div class=\"option\" data-option-key=\"option1\" data-is-correct=\"false\">\r\n                    Equal to load factor in determinate structures                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option2\" data-is-correct=\"true\">\r\n                    More than the load factor in determinate structures                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option3\" data-is-correct=\"false\">\r\n                    Less than the load factor in determinate structures                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option4\" data-is-correct=\"false\">\r\n                    Unpredictable                <\/div>\r\n                            \r\n            <!-- Feedback messages for non-AMP -->\r\n            <div class=\"feedback\" data-feedback=\"wrong\">Answer is Right!<\/div>\r\n            <div class=\"feedback\" data-feedback=\"right\">Answer is Wrong!<\/div>\r\n        <\/div>\r\n\r\n        <script>\r\n        document.addEventListener('DOMContentLoaded', function () {\r\n            var containers = document.querySelectorAll('.mcq-container');\r\n\r\n            containers.forEach(function(container) {\r\n                var options = container.querySelectorAll('.option');\r\n                var feedbackSelect = container.querySelector('[data-feedback=\"select\"]');\r\n                var feedbackWrong = container.querySelector('[data-feedback=\"wrong\"]');\r\n                var feedbackRight = container.querySelector('[data-feedback=\"right\"]');\r\n\r\n                options.forEach(function(option) {\r\n                    option.addEventListener('click', function() {\r\n                        var selectedOption = option.getAttribute('data-option-key');\r\n                        var isCorrect = option.getAttribute('data-is-correct') === 'true';\r\n\r\n                        \/\/ Remove previous selections\r\n                        options.forEach(function(opt) {\r\n                            opt.classList.remove('correct', 'incorrect');\r\n                        });\r\n\r\n                        \/\/ Add the correct\/incorrect class\r\n                        if (isCorrect) {\r\n                            option.classList.add('correct');\r\n                            feedbackRight.hidden = false;\r\n                            feedbackWrong.hidden = true;\r\n                        } else {\r\n                            option.classList.add('incorrect');\r\n                            feedbackRight.hidden = true;\r\n                            feedbackWrong.hidden = false;\r\n                        }\r\n\r\n                        \/\/ Hide select feedback\r\n                        feedbackSelect.hidden = true;\r\n                    });\r\n                });\r\n            });\r\n        });\r\n        <\/script>\r\n    \r\n    <!--more--><\/p>\n<p>The correct answer is: <strong>B. More than the load factor in determinate structures<\/strong>.<\/p>\n<p>A determinate structure is a structure in which the internal forces can be determined by static equilibrium alone. An indeterminate structure is a structure in <div class=\"youtube-subscribe-container\">\r\n        <a href=\"https:\/\/www.youtube.com\/channel\/UCNHT8lW-JmLC68rjBfZhdkg?sub_confirmation=1\" target=\"_blank\" class=\"youtube-subscribe-button\">\r\n            <span class=\"youtube-icon\">\r\n                <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\">\r\n                    <path d=\"M549.7 124.1c-6.3-23.7-24.8-42.3-48.3-48.6C458.8 64 288 64 288 64S117.2 64 74.6 75.5c-23.5 6.3-42 24.9-48.3 48.6-11.4 42.9-11.4 132.3-11.4 132.3s0 89.4 11.4 132.3c6.3 23.7 24.8 41.5 48.3 47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Subscribe on YouTube\r\n        <\/a>\r\n    <\/div> which the internal forces cannot be determined by static equilibrium alone and additional information, such as the deformation of <div class=\"telegram-channel-container\">\r\n        <a href=\"https:\/\/t.me\/pscnotes2025\" target=\"_blank\" class=\"telegram-channel-button\">\r\n            <span class=\"telegram-icon\">\r\n                <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 496 512\">\r\n                    <path fill=\"white\" d=\"M248,8C111,8,0,119,0,256s111,248,248,248s248-111,248-248S385,8,248,8z M362,177L320,367c-3,14-10,18-20,14l-56-41l-27,26 c-3,3-5,5-10,5l4-63L323,196c5-5-1-7-8-3l-98,62l-42-13c-9-3-10-9,2-14l162-63C351,160,365,164,362,177z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Join Our Telegram Channel\r\n        <\/a>\r\n    <\/div> the structure, is required.<\/p>\n<p>The load factor is a factor that is used to increase the design loads on a structure to account for uncertainties in the loads and the strength of the materials. The load factor is typically greater for indeterminate structures than for determinate structures because indeterminate structures are more susceptible to failure due to unforeseen loads or material defects.<\/p>\n<p>Here is a brief explanation of each option:<\/p>\n<ul>\n<li>Option A: Equal to load factor in determinate structures. This is not correct because the load factor is typically greater for indeterminate structures than for determinate structures.<\/li>\n<li>Option B: More than the load factor in determinate structures. This is the correct answer because indeterminate structures are more susceptible to failure due to unforeseen loads or material defects.<\/li>\n<li>Option C: Less than the load factor in determinate structures. This is not correct because the load factor is typically greater for indeterminate structures than for determinate structures.<\/li>\n<li>Option D: Unpredictable. This is not correct because the load factor can be determined based on the type of structure and the loads that it will be subjected to.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Join Our Telegram Channel Subscribe on YouTube<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[642],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable\" \/>\n<meta property=\"og:description\" content=\"Subscribe on YouTube\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-15T02:22:23+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/","og_locale":"en_US","og_type":"article","og_title":"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable","og_description":"Subscribe on YouTube","og_url":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-15T02:22:23+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/","url":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/","name":"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-15T02:22:23+00:00","dateModified":"2024-04-15T02:22:23+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/other-conditions-being-same-the-load-factor-in-indeterminate-structures-is-a-equal-to-load-factor-in-determinate-structures-b-more-than-the-load-factor-in-determinate-structures-c-less-than-the-lo\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"mcq","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/"},{"@type":"ListItem","position":3,"name":"Civil engineering","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/civil-engineering\/"},{"@type":"ListItem","position":4,"name":"Design of steel structures","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/civil-engineering\/design-of-steel-structures\/"},{"@type":"ListItem","position":5,"name":"Other conditions being same, the load factor in indeterminate structures is A. Equal to load factor in determinate structures B. More than the load factor in determinate structures C. Less than the load factor in determinate structures D. Unpredictable"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/6000"}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=6000"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/6000\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=6000"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=6000"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=6000"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}