{"id":58861,"date":"2024-04-16T01:26:56","date_gmt":"2024-04-16T01:26:56","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=58861"},"modified":"2024-04-16T01:26:56","modified_gmt":"2024-04-16T01:26:56","slug":"inter-pole-flux-should-be-sufficient-to","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/","title":{"rendered":"Inter-pole flux should be sufficient to"},"content":{"rendered":"<p>[amp_mcq option1=&#8221;Neutralize the commutating self induced e.m.f.&#8221; option2=&#8221;Neutralize the armature reaction flux&#8221; option3=&#8221;Neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil&#8221; option4=&#8221;Perform none of the above functions&#8221; correct=&#8221;option3&#8243;]<!--more--><\/p>\n<p>The correct answer is C.<\/p>\n<p>The inter-pole flux should be sufficient to neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil.<\/p>\n<p>The armature reaction flux is the flux produced by the current flowing through the armature windings. This flux interacts with the main field flux to produce a net flux that can cause the brushes to shift from their correct position. The commutating e.m.f. is the e.m.f. that is induced in the coil as it is being commutated. This e.m.f. can cause sparking at the brushes.<\/p>\n<p>The inter-pole flux is produced by the current flowing through the inter-pole windings. This flux opposes the armature reaction flux and helps to keep the brushes in their correct position. It also helps to reduce sparking at the brushes.<\/p>\n<p>If the inter-pole flux is not sufficient, the armature reaction flux will cause the brushes to shift from their correct position. This can cause sparking at the brushes and can also lead to a loss of power.<\/p>\n<p>If the inter-pole flux is too strong, it can cause the coil to overheat. This can damage the coil and can also lead to a loss of power.<\/p>\n<p>Therefore, the inter-pole flux should be sufficient to neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[amp_mcq option1=&#8221;Neutralize the commutating self induced e.m.f.&#8221; option2=&#8221;Neutralize the armature reaction flux&#8221; option3=&#8221;Neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil&#8221; option4=&#8221;Perform none of the above functions&#8221; correct=&#8221;option3&#8243;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[742],"tags":[],"class_list":["post-58861","post","type-post","status-publish","format-standard","hentry","category-d-c-generators","no-featured-image-padding"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Inter-pole flux should be sufficient to<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Inter-pole flux should be sufficient to\" \/>\n<meta property=\"og:description\" content=\"[amp_mcq option1=&#8221;Neutralize the commutating self induced e.m.f.&#8221; option2=&#8221;Neutralize the armature reaction flux&#8221; option3=&#8221;Neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil&#8221; option4=&#8221;Perform none of the above functions&#8221; correct=&#8221;option3&#8243;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-16T01:26:56+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Inter-pole flux should be sufficient to","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/","og_locale":"en_US","og_type":"article","og_title":"Inter-pole flux should be sufficient to","og_description":"[amp_mcq option1=&#8221;Neutralize the commutating self induced e.m.f.&#8221; option2=&#8221;Neutralize the armature reaction flux&#8221; option3=&#8221;Neutralize both the armature reaction flux as well as commutating e.m.f. induced in the coil&#8221; option4=&#8221;Perform none of the above functions&#8221; correct=&#8221;option3&#8243;]","og_url":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-16T01:26:56+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/","url":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/","name":"Inter-pole flux should be sufficient to","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-16T01:26:56+00:00","dateModified":"2024-04-16T01:26:56+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/inter-pole-flux-should-be-sufficient-to\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"mcq","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/"},{"@type":"ListItem","position":3,"name":"Electrical engineering","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/electrical-engineering\/"},{"@type":"ListItem","position":4,"name":"D.c. Generators","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/mcq\/electrical-engineering\/d-c-generators\/"},{"@type":"ListItem","position":5,"name":"Inter-pole flux should be sufficient to"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/58861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=58861"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/58861\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=58861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=58861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=58861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}