{"id":44418,"date":"2024-04-15T21:43:27","date_gmt":"2024-04-15T21:43:27","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=44418"},"modified":"2024-04-15T21:43:27","modified_gmt":"2024-04-15T21:43:27","slug":"the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/","title":{"rendered":"The power developed by a synchronous motor will be maximum when the load angle is"},"content":{"rendered":"<p>[amp_mcq option1=&#8221;zero&#8221; option2=&#8221;45\u00c2\u00b0&#8221; option3=&#8221;90\u00c2\u00b0&#8221; option4=&#8221;120\u00c2\u00b0&#8221; correct=&#8221;option3&#8243;]<!--more--><\/p>\n<p>The power developed by a synchronous motor will be maximum when the load angle is zero.<\/p>\n<p>The load angle is the angle between the rotor and stator magnetic fields. When the load angle is zero, the two fields are aligned and the motor is operating at its maximum power.<\/p>\n<p>When the load angle is greater than zero, the rotor field is lagging behind the stator field. This causes the motor to operate at a lower power.<\/p>\n<p>When the load angle is greater than 90 degrees, the rotor field is leading the stator field. This causes the motor to operate at a negative power, which means that it is acting as a generator.<\/p>\n<p>Therefore, the power developed by a synchronous motor will be maximum when the load angle is zero.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[amp_mcq option1=&#8221;zero&#8221; option2=&#8221;45\u00c2\u00b0&#8221; option3=&#8221;90\u00c2\u00b0&#8221; option4=&#8221;120\u00c2\u00b0&#8221; correct=&#8221;option3&#8243;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[965],"tags":[],"class_list":["post-44418","post","type-post","status-publish","format-standard","hentry","category-synchronous-motors","no-featured-image-padding"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>The power developed by a synchronous motor will be maximum when the load angle is<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The power developed by a synchronous motor will be maximum when the load angle is\" \/>\n<meta property=\"og:description\" content=\"[amp_mcq option1=&#8221;zero&#8221; option2=&#8221;45\u00c2\u00b0&#8221; option3=&#8221;90\u00c2\u00b0&#8221; option4=&#8221;120\u00c2\u00b0&#8221; correct=&#8221;option3&#8243;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-15T21:43:27+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"The power developed by a synchronous motor will be maximum when the load angle is","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/","og_locale":"en_US","og_type":"article","og_title":"The power developed by a synchronous motor will be maximum when the load angle is","og_description":"[amp_mcq option1=&#8221;zero&#8221; option2=&#8221;45\u00c2\u00b0&#8221; option3=&#8221;90\u00c2\u00b0&#8221; option4=&#8221;120\u00c2\u00b0&#8221; correct=&#8221;option3&#8243;]","og_url":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-15T21:43:27+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/","url":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/","name":"The power developed by a synchronous motor will be maximum when the load angle is","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-15T21:43:27+00:00","dateModified":"2024-04-15T21:43:27+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/the-power-developed-by-a-synchronous-motor-will-be-maximum-when-the-load-angle-is\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"Synchronous motors","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/synchronous-motors\/"},{"@type":"ListItem","position":3,"name":"The power developed by a synchronous motor will be maximum when the load angle is"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/44418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=44418"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/44418\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=44418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=44418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=44418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}