{"id":43908,"date":"2024-04-15T21:36:09","date_gmt":"2024-04-15T21:36:09","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=43908"},"modified":"2024-04-15T21:36:09","modified_gmt":"2024-04-15T21:36:09","slug":"air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/","title":{"rendered":"Air blast circuit breakers for 400 kV power system are designed to operate in"},"content":{"rendered":"<p>[amp_mcq option1=&#8221;100 microsecond&#8221; option2=&#8221;50 millisecond&#8221; option3=&#8221;0.5 sec&#8221; option4=&#8221;0.1 sec&#8221; correct=&#8221;option1&#8243;]<!--more--><\/p>\n<p>The correct answer is A. 100 microsecond.<\/p>\n<p>Air blast circuit breakers are designed to interrupt high-current circuits. They do this by creating a blast of air that extinguishes the arc between the contacts. The speed at which the arc is extinguished is important, as it determines the amount of energy that is released in the system. A faster arc interruption results in less energy being released, which can reduce the risk of damage to the system.<\/p>\n<p>Air blast circuit breakers for 400 kV power systems are designed to operate in 100 microseconds. This is because the higher the voltage, the faster the arc must be extinguished to prevent damage to the system.<\/p>\n<p>Option B, 50 milliseconds, is too slow. This would result in too much energy being released in the system, which could cause damage.<\/p>\n<p>Option C, 0.5 seconds, is also too slow. This would still result in too much energy being released in the system, and it would also take too long to interrupt the circuit, which could cause problems for the system.<\/p>\n<p>Option D, 0.1 seconds, is the fastest of the options, but it is still too slow for a 400 kV power system. The arc must be extinguished in 100 microseconds or less to prevent damage to the system.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[amp_mcq option1=&#8221;100 microsecond&#8221; option2=&#8221;50 millisecond&#8221; option3=&#8221;0.5 sec&#8221; option4=&#8221;0.1 sec&#8221; correct=&#8221;option1&#8243;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[962],"tags":[],"class_list":["post-43908","post","type-post","status-publish","format-standard","hentry","category-switchgear-protections","no-featured-image-padding"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Air blast circuit breakers for 400 kV power system are designed to operate in<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Air blast circuit breakers for 400 kV power system are designed to operate in\" \/>\n<meta property=\"og:description\" content=\"[amp_mcq option1=&#8221;100 microsecond&#8221; option2=&#8221;50 millisecond&#8221; option3=&#8221;0.5 sec&#8221; option4=&#8221;0.1 sec&#8221; correct=&#8221;option1&#8243;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-15T21:36:09+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Air blast circuit breakers for 400 kV power system are designed to operate in","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/","og_locale":"en_US","og_type":"article","og_title":"Air blast circuit breakers for 400 kV power system are designed to operate in","og_description":"[amp_mcq option1=&#8221;100 microsecond&#8221; option2=&#8221;50 millisecond&#8221; option3=&#8221;0.5 sec&#8221; option4=&#8221;0.1 sec&#8221; correct=&#8221;option1&#8243;]","og_url":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-15T21:36:09+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/","url":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/","name":"Air blast circuit breakers for 400 kV power system are designed to operate in","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-15T21:36:09+00:00","dateModified":"2024-04-15T21:36:09+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/air-blast-circuit-breakers-for-400-kv-power-system-are-designed-to-operate-in\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"Switchgear protections","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/switchgear-protections\/"},{"@type":"ListItem","position":3,"name":"Air blast circuit breakers for 400 kV power system are designed to operate in"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/761a7274f9cce048fa5b921221e7934820d74514df93ef195a9d22af0c1c9001?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/43908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=43908"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/43908\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=43908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=43908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=43908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}