{"id":43866,"date":"2024-04-15T21:35:35","date_gmt":"2024-04-15T21:35:35","guid":{"rendered":"https:\/\/exam.pscnotes.com\/mcq\/?p=43866"},"modified":"2024-04-15T21:35:35","modified_gmt":"2024-04-15T21:35:35","slug":"gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds","status":"publish","type":"post","link":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/","title":{"rendered":"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds"},"content":{"rendered":"<p>\r\n    <!-- Check if it's an AMP page -->\r\n            <!-- Non-AMP version -->\r\n        <div class=\"mcq-container\" data-quiz-id=\"quizState_6a970d5f7edcc\">\r\n                                            <div class=\"option\" data-option-key=\"option1\" data-is-correct=\"false\">\r\n                    50\u00c2\u00b0C                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option2\" data-is-correct=\"false\">\r\n                    80\u00c2\u00b0C                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option3\" data-is-correct=\"false\">\r\n                    100\u00c2\u00b0C                <\/div>\r\n                                            <div class=\"option\" data-option-key=\"option4\" data-is-correct=\"true\">\r\n                    150\u00c2\u00b0C                <\/div>\r\n                            \r\n            <!-- Feedback messages for non-AMP -->\r\n            <div class=\"feedback\" data-feedback=\"wrong\">Answer is Right!<\/div>\r\n            <div class=\"feedback\" data-feedback=\"right\">Answer is Wrong!<\/div>\r\n        <\/div>\r\n\r\n        <script>\r\n        document.addEventListener('DOMContentLoaded', function () {\r\n            var containers = document.querySelectorAll('.mcq-container');\r\n\r\n            containers.forEach(function(container) {\r\n                var options = container.querySelectorAll('.option');\r\n                var feedbackSelect = container.querySelector('[data-feedback=\"select\"]');\r\n                var feedbackWrong = container.querySelector('[data-feedback=\"wrong\"]');\r\n                var feedbackRight = container.querySelector('[data-feedback=\"right\"]');\r\n\r\n                options.forEach(function(option) {\r\n                    option.addEventListener('click', function() {\r\n                        var selectedOption = option.getAttribute('data-option-key');\r\n                        var isCorrect = option.getAttribute('data-is-correct') === 'true';\r\n\r\n                        \/\/ Remove previous selections\r\n                        options.forEach(function(opt) {\r\n                            opt.classList.remove('correct', 'incorrect');\r\n                        });\r\n\r\n                        \/\/ Add the correct\/incorrect class\r\n                        if (isCorrect) {\r\n                            option.classList.add('correct');\r\n                            feedbackRight.hidden = false;\r\n                            feedbackWrong.hidden = true;\r\n                        } else {\r\n                            option.classList.add('incorrect');\r\n                            feedbackRight.hidden = true;\r\n                            feedbackWrong.hidden = false;\r\n                        }\r\n\r\n                        \/\/ Hide select feedback\r\n                        feedbackSelect.hidden = true;\r\n                    });\r\n                });\r\n            });\r\n        });\r\n        <\/script>\r\n    \r\n    <!--more--><\/p>\n<p>The correct answer is: D. 150\u00c2\u00b0C<\/p>\n<p>Transformer oil is a dielectric fluid used to insulate and cool the windings of a transformer. It is a non-flammable, non-toxic liquid that is typically made from mineral oil or synthetic oil.<\/p>\n<p>The oil temperature in a transformer is typically kept below 150\u00c2\u00b0C to prevent the oil from breaking down and releasing gas. If the oil temperature exceeds 150\u00c2\u00b0C, the oil can start to decompose and release gas. This gas can cause arcing and sparking, which can lead to a fire or explosion.<\/p>\n<p>Therefore, gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds 150\u00c2\u00b0C.<\/p>\n<p>Option A: 50\u00c2\u00b0C is too low a temperature to cause the oil to decompose.<\/p>\n<p>Option B: 80\u00c2\u00b0C is a possible temperature at which the oil could start to decompose, but it is not the most likely temperature.<\/p>\n<p>Option C: 100\u00c2\u00b0C is a more likely temperature at which the oil could start to decompose, but it is still not the most likely <div class=\"youtube-subscribe-container\">\r\n        <a href=\"https:\/\/www.youtube.com\/channel\/UCNHT8lW-JmLC68rjBfZhdkg?sub_confirmation=1\" target=\"_blank\" class=\"youtube-subscribe-button\">\r\n            <span class=\"youtube-icon\">\r\n          <div class=\"telegram-channel-container\">\r\n        <a href=\"https:\/\/t.me\/pscnotes2025\" target=\"_blank\" class=\"telegram-channel-button\">\r\n            <span class=\"telegram-icon\">\r\n                <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 496 512\">\r\n                    <path fill=\"white\" d=\"M248,8C111,8,0,119,0,256s111,248,248,248s248-111,248-248S385,8,248,8z M362,177L320,367c-3,14-10,18-20,14l-56-41l-27,26 c-3,3-5,5-10,5l4-63L323,196c5-5-1-7-8-3l-98,62l-42-13c-9-3-10-9,2-14l162-63C351,160,365,164,362,177z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Join Our Telegram Channel\r\n        <\/a>\r\n    <\/div>       <svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 576 512\">\r\n                    <path d=\"M549.7 124.1c-6.3-23.7-24.8-42.3-48.3-48.6C458.8 64 288 64 288 64S117.2 64 74.6 75.5c-23.5 6.3-42 24.9-48.3 48.6-11.4 42.9-11.4 132.3-11.4 132.3s0 89.4 11.4 132.3c6.3 23.7 24.8 41.5 48.3 47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z\"\/>\r\n                <\/svg>\r\n            <\/span>\r\n            Subscribe on YouTube\r\n        <\/a>\r\n    <\/div> temperature.<\/p>\n<p>Option D: 150\u00c2\u00b0C is the most likely temperature at which the oil will start to decompose and release gas.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Subscribe on YouTube<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[960],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v22.2 (Yoast SEO v23.3) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds\" \/>\n<meta property=\"og:description\" content=\"Join Our Telegram Channel Subscribe on YouTube\" \/>\n<meta property=\"og:url\" content=\"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/\" \/>\n<meta property=\"og:site_name\" content=\"MCQ and Quiz for Exams\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-15T21:35:35+00:00\" \/>\n<meta name=\"author\" content=\"rawan239\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"rawan239\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/","og_locale":"en_US","og_type":"article","og_title":"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds","og_description":"Join Our Telegram Channel Subscribe on YouTube","og_url":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/","og_site_name":"MCQ and Quiz for Exams","article_published_time":"2024-04-15T21:35:35+00:00","author":"rawan239","twitter_card":"summary_large_image","twitter_misc":{"Written by":"rawan239","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/","url":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/","name":"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds","isPartOf":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#website"},"datePublished":"2024-04-15T21:35:35+00:00","dateModified":"2024-04-15T21:35:35+00:00","author":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209"},"breadcrumb":{"@id":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/exam.pscnotes.com\/mcq\/gas-is-usually-not-liberated-due-to-dissociation-of-transformer-oil-unless-the-oil-temperature-exceeds\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/exam.pscnotes.com\/mcq\/"},{"@type":"ListItem","position":2,"name":"Transformers","item":"https:\/\/exam.pscnotes.com\/mcq\/category\/transformers\/"},{"@type":"ListItem","position":3,"name":"Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds"}]},{"@type":"WebSite","@id":"https:\/\/exam.pscnotes.com\/mcq\/#website","url":"https:\/\/exam.pscnotes.com\/mcq\/","name":"MCQ and Quiz for Exams","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/exam.pscnotes.com\/mcq\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/5807dafeb27d2ec82344d6cbd6c3d209","name":"rawan239","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/exam.pscnotes.com\/mcq\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d97f17072bfa490596c8f78363955d55?s=96&d=mm&r=g","caption":"rawan239"},"sameAs":["https:\/\/exam.pscnotes.com"],"url":"https:\/\/exam.pscnotes.com\/mcq\/author\/rawan239\/"}]}},"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/43866"}],"collection":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/comments?post=43866"}],"version-history":[{"count":0,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/posts\/43866\/revisions"}],"wp:attachment":[{"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/media?parent=43866"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/categories?post=43866"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/exam.pscnotes.com\/mcq\/wp-json\/wp\/v2\/tags?post=43866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}