21. The operating voltage of super-tension cables is up to

3.3 kV
6.6 kV
11 kV
33 kV

Subscribe on YouTube
button" href="https://exam.pscnotes.com/mcq/the-operating-voltage-of-super-tension-cables-is-up-to/#more-55872">Detailed SolutionThe operating voltage of super-tension cables is up to

22. In a D.C. 3-wire distributor using balancers and having unequal loads on the two sides

both balancers run as generators
both balancers run as motors

Detailed SolutionIn a D.C. 3-wire distributor using balancers and having unequal loads on the two sides

23. A uniformly loaded D.C. distributor is fed at both ends with equal voltages. As compared to a similar distributor fed at one end only, the drop at the middle point is

One-fourth
One-third
distributor is fed at both ends with equal voltages. As compared to a similar distributor fed at one end only, the drop at the middle point is A. One-fourth B. One-third C. One-half
Twice

Detailed SolutionA uniformly loaded D.C. distributor is fed at both ends with equal voltages.

As compared to a similar distributor fed at one end only, the drop at the middle point is

24. ________ are the conductors, which connect the consumer’s terminals to the distribution.

Distributors
Service mains
Feeders
None of the above

Join Our Telegram Channel

47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube
the distribution." class="read-more button" href="https://exam.pscnotes.com/mcq/________-are-the-conductors-which-connect-the-consumers-terminals-to-the-distribution/#more-53273">Detailed Solution________ are the conductors, which connect the consumer’s terminals to the distribution.

25. A feeder, in a transmission system, feeds power to

Distributors
Generating stations
Service mains
All of the above

Subscribe on YouTube
class="read-more button" href="https://exam.pscnotes.com/mcq/a-feeder-in-a-transmission-system-feeds-power-to/#more-53264">Detailed SolutionA feeder, in a transmission system, feeds power to

26. The steel used in steel cored conductors is usually

Alloy steel
Stainless steel
Mild steel
High speed steel

Join Our Telegram Channel

64 288 64 288 64S117.2 64 74.6 75.5c-23.5 6.3-42 24.9-48.3 48.6-11.4 42.9-11.4 132.3-11.4 132.3s0 89.4 11.4 132.3c6.3 23.7 24.8 41.5 48.3 47.8C117.2 448 288 448 288 448s170.8 0 213.4-11.5c23.5-6.3 42-24.2 48.3-47.8 11.4-42.9 11.4-132.3 11.4-132.3s0-89.4-11.4-132.3zm-317.5 213.5V175.2l142.7 81.2-142.7 81.2z"/> Subscribe on YouTube usually" class="read-more button" href="https://exam.pscnotes.com/mcq/the-steel-used-in-steel-cored-conductors-is-usually/#more-53236">Detailed SolutionThe steel used in steel cored conductors is usually

27. There is a greater possibility of occurrence of corona during

Dry weather
Winter
Summer heat
Humid weather

Detailed Solution

Subscribe on YouTube
class="screen-reader-text">There is a greater possibility of occurrence of corona during

28. The effect of corona can be detected by

Presence of ozone detected by odour
Hissing sound
Faint luminous glow of bluish color
All of the above

Subscribe on YouTube
effect of corona can be detected by" class="read-more button" href="https://exam.pscnotes.com/mcq/the-effect-of-corona-can-be-detected-by/#more-52518">Detailed SolutionThe effect of corona can be detected by

29. The phenomenon of rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the

See-back effect
Ferranti effect
Raman effect
None of the above

Detailed

SolutionThe phenomenon of rise in voltage at the receiving end of the open-circuited or lightly loaded line is called the

30. The underground system cannot be operated above

440 V
11 V
33 V
66 V

Subscribe on YouTube
button" href="https://exam.pscnotes.com/mcq/the-underground-system-cannot-be-operated-above/#more-52403">Detailed SolutionThe underground system cannot be operated above