href="https://exam.pscnotes.com/mcq/the-chemical-used-in-breather-is/#more-58150">Detailed SolutionThe chemical used in breather is

14. The noise produced by a transformer is termed as

zoom
hum
ringing
buzz

Detailed

SolutionThe noise produced by a transformer is termed as

15. The no-load current drawn by transformer is usually what per cent of the full-load current?

0.2 to 0.5 per cent
2 to 5 per cent
12 to 15 per cent
20 to 30 per cent

Subscribe on YouTube
cent of the full-load current?" class="read-more button" href="https://exam.pscnotes.com/mcq/the-no-load-current-drawn-by-transformer-is-usually-what-per-cent-of-the-full-load-current/#more-57798">Detailed SolutionThe no-load current drawn by transformer is usually what per cent of the full-load current?

16. The power factor of an induction motor under no-load conditions will be closer to

0.2 lagging
0.2 leading
0.5 leading
unity

Subscribe on YouTube
to" class="read-more button" href="https://exam.pscnotes.com/mcq/the-power-factor-of-an-induction-motor-under-no-load-conditions-will-be-closer-to/#more-57791">Detailed SolutionThe power factor of an induction motor under no-load conditions will be closer to

17. In Ns is the synchronous speed and s the slip, then actual running speed of an induction motor will be

Ns
s.Ns
(1 - s)Ns
(Ns - 1)s

Subscribe on YouTube

induction motor will be" class="read-more
Join Our Telegram Channel
button" href="https://exam.pscnotes.com/mcq/in-ns-is-the-synchronous-speed-and-s-the-slip-then-actual-running-speed-of-an-induction-motor-will-be/#more-57635">Detailed SolutionIn Ns is the synchronous speed and s the slip, then actual running speed of an induction motor will be

18. If a transformer is continuously operated the maximum temperature rise will occur in

core
windings
tank
any of the above

Subscribe on YouTube
occur in" class="read-more button" href="https://exam.pscnotes.com/mcq/if-a-transformer-is-continuously-operated-the-maximum-temperature-rise-will-occur-in/#more-57618">Detailed SolutionIf a transformer is continuously operated the maximum temperature rise will occur in

19. The chemical used in breather for transformer should have the quality of

ionizing air
absorbing moisture
cleansing the transformer oil
cooling the transformer oil

Subscribe on YouTube
quality of" class="read-more button" href="https://exam.pscnotes.com/mcq/the-chemical-used-in-breather-for-transformer-should-have-the-quality-of/#more-57512">Detailed SolutionThe chemical used in breather for transformer should have the quality of

20. Buchholz’s relay gives warning and protection against

electrical fault inside the transformer itself
electrical fault outside the transformer in outgoing feeder
for both outside and inside faults
none of the above

Detailed SolutionBuchholz’s relay gives warning and protection against


Test 1Test 2Test 3