Skip to content

MCQ and Quiz for Exams

  • Home
  • Telangana and Karnataka
  • Bihar
  • Haryana
  • Assam
  • Jammu and kashmir
  • Login

Electrical control systems

21. Which of the following is an electromagnetically device ?

Induction relay
Thermocouple
LVDT
Any of the above E. None of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionWhich of the following is an electromagnetically device ?

Join Our Telegram Channel

Subscribe on YouTube

22. Which of the following statements is correct for any closed loop system ?

All the co-efficients can have zero value
All the co-efficients are always non-zero
Only one of the static error co-efficients has a finite non-zero value
None of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionWhich of the following statements is correct for any closed loop system ?

Join Our Telegram Channel

Subscribe on YouTube

23. Which of the following should be done to make an unstable system stable ?

The gain of the system should be decreased
The gain of the system should be increased
The number of poles to the loop transfer function should be increased
The number of zeros to the loop transfer function should be increased
Answer is Right!
Answer is Wrong!

Detailed SolutionWhich of the following should be done to make an unstable system stable ?

Subscribe on YouTube

Join Our Telegram Channel

24. The transfer function technique is considered as inadequate under which of the following conditions ?

Systems having complexities and non-linearities
Systems having stability problems
Systems having multiple input disturbances
All of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionThe transfer function technique is considered as inadequate under which of the following conditions ?

Join Our Telegram Channel

Subscribe on YouTube

25. A phase lag lead network introduces in the output

lag at all frequencies
lag at high frequencies and lead at low frequencies
lag at low frequencies and lead at high frequencies
none of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionA phase lag lead network introduces in the output

Join Our Telegram Channel

Subscribe on YouTube

26. In a system zero initial condition means that

The system is at rest and no energy is stored in any of its components
The system is working with zero stored energy
The system is working with zero reference signal
None of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionIn a system zero initial condition means that

Join Our Telegram Channel

Subscribe on YouTube

27. An amplidyne can give which of the following characteristics ?

Constant current
Constant voltage
Constant current as well as constant voltage
Constant current, constant voltage and constant power E. None of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionAn amplidyne can give which of the following characteristics ?

Subscribe on YouTube

Join Our Telegram Channel

28. Addition of zeros in transfer function causes which of the following?

Lead-compensation
Lag-compensation
Lead-lag compensation
None of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionAddition of zeros in transfer function causes which of the following?

Join Our Telegram Channel

Subscribe on YouTube

29. Pressure error can be measured by which of the following ?

Differential bellows and straingauge
Selsyn
Strain gauge
Strain gauge and potentiometer
Answer is Right!
Answer is Wrong!

Detailed SolutionPressure error can be measured by which of the following ?

Join Our Telegram Channel

Subscribe on YouTube

30. In a control system integral error compensation _______ steady state error

increases
minimizes
does not have any effect on
any of the above
Answer is Right!
Answer is Wrong!

Detailed SolutionIn a control system integral error compensation _______ steady state error

Join Our Telegram Channel

Subscribe on YouTube
Page 1Page 2Page 3Page 4Page 5

Test 1Test 2
© PSC Notes- Serving since 2015
Scroll back to top
  • Home
  • Telangana and Karnataka
  • Bihar
  • Haryana
  • Assam
  • Jammu and kashmir
  • Login
Go to mobile version